A.M. X-Ray Service Inc. - Illuminating solutions in Healthcare Informatics X-ray Generators: C-Arms, Chiropractic Systems, Digital Systems, High Frequency Generators, Hospital Grade Systems, Line Frequency Generators, Orthopedic Systems, Podiatry Systems, Portable X-ray Systems and Veterinary Systems Medical Displays Computed Radiography (CR) Direct Radiography (DR) Picture Archive and Communications Systems (PACS) Accessories and Parts

Home » X-ray Generators » Portable X-ray Systems » All Products

 Checkout

GE AMX4+ Portable X-ray System
GE AMX4+ Portable X-ray System

Details 

Our service team has more than 50 years of combined experience supporting various imaging modalities including radiography, fluoroscopy, catheterization and angioscopy. We provide a high quality affordable alternative to OEM services.

For repair service contact us now by phone @ 1-877-926-9729

G.E. AMX4+ new units available.

  • New unit
  • Varian Rad10 X-ray tube (Classic AMX4 tube)
  • 1 year manufacturers warranty on tube
  • 1 year parts only warranty on system
  • $38,000 + shipping
  • Exchange units accepted.

Tingle TXR - GP-10 SP-HF-2.0 Portable Systems
Tingle TXR - GP-10 SP-HF-2.0 Portable Systems

Details 

50 mA HF Portable System

HF-2.0 Constant Potential High Frequency Generator

  • 2.0 kW Constant Potential
  • 40 to 110 kVp in 1 kVp steps
  • 12 mA Stations; 4, 5, 6, 8, 10, 12.5, 16, 20, 25, 32, 40, & 50
  • 0.002-10 Second exposure time range, 38 total in 25% steps
  • 0.1 to 100 mAs
  • 0.6 mm x 1.5 mm. Dual focal spot stationary anode tube, 40,000 HU
  • 110VAC, 15 Amp or 230VAC, 7 Amp power line requirement

Power Cord ? 20 feet long

Exposure Cord ? 10 feet long

Stand

  • Stand on base with wheels for easy maneuverability
  • Gas spring arm supports tube to accommodate easy positioning
  • Positive mechanical brakes
  • Cassette storage box accommodates up to 8 cassettes
  • 15? to 81.5? Vertical tube travel
  • 132 Lbs. total weight

Collimator ? Certified manual


Tingle TXR - GP-10 SP-HF-4.0 Portable Systems
Tingle TXR - GP-10 SP-HF-4.0 Portable Systems

Details 

100 mA. HF Portable System

HF-4.0 Constant Potential High Frequency Generator

  • 4.0 kW Constant Potential
  • 40 to 115 kVp in 1 kVp steps
  • 15 mA Stations; 4, 5, 6, 8, 10, 12.5, 16, 20, 25, 32, 40, 50, 64, 80 & 100
  • 0.001-10 Second exposure time range, 38 total in 25% steps
  • 0.1 to 200 mAs
  • 0.6 mm x 1.5 mm. Dual focal spot stationary anode tube, 40,000 HU
  • 110VAC, 24 Amp or 230VAC, 12A power line requirement

Power Cord ? 20 feet long

Exposure Cord ? 10 feet long

Stand

  • Stand on base with wheels for easy maneuverability
  • Gas spring arm supports tube to accommodate easy positioning
  • Positive mechanical brakes
  • Cassette storage box accommodates up to 8 cassettes
  • 15? to 81.5? Vertical tube travel
  • 132 Lbs. total weight

Collimator ? Certified manual



Email Us at Contact@AMXRayService.com