Optima U.R.S. SEU-MA - Hospital Grade System Universal Radiographic System, URS-Fixed Grid
Features:
Multipurpose Radiological System for Thorax, abdomen, skeleton, skull and spinal column
Solid floor-to wall column without need for maintenance.
Rotating Arm allowing for Vertical, Horizontal and Oblique Diagnosis.
Variable SID from 1 meter to 2 meters. (40" - 72").
Three Electromagnetic Brakes strategically located at Collimator Control, Arm and Electromagnetic.
Brake Release Push Button located at Top of Grid Cabinet greatly facilitates patient positioning.
Possibility of making Lateral Procedures with the patient lying down.
Grid Cabinet with 90° Rotation.
Easy Interchangeable Grid.
Including one Grid 103 Lines. Ratio 10:1 focalized at 1.5 meters (59").
Cassette Tray for cassette sizes up to 43/43 cm (17"x17").
Tingle TXR - Patient Table Semer-0001
Details
Patient Table Semer-0001 - Hospital Grade System, Universal Radiography System - URS-Fixed Grid
Features:
Moving Table with large diameter wheels that allows for easy movement
Pressure Brakes on front wheels
Length 2000 mm (78.75")
Height 700 mm (27.5")
Wide 650 mm (25.5")
Collimator SCOL-302T
Manual Collimator
Up to 43x43 cm (17"x17")
Electronic Timer for the Collimator Lamp
X-RAY TUBE E7239X FROM TOSHIBA
Rotating Anode 16°. Low Speed
125 kVp
140 kHU
Dual Focal Spots: Small Focus 1.0 21kW (50Hz) - 23kW ( 60Hz)
Large Focus 2.0 45kW (50Hz) - 47kW ( 60Hz)
High Tension Cables: HT6
Two Ultra Flexible High Tension Cables 75 kVp, 6 meters (19.7')
Options:
Super Speed Bucky
Compression Band
Tingle TXR - SHF 310
Details
Tingle TXR - SHF 310, Hospital Grade System - Universal Radiographic System, URS-Fixed Grid
X-ray Generator SHF 310: with APR 32kW, 125 kVp, 1 Tube, 400 mA, 1Ph.220/240 VAC
High Frequency, 1 Tube Operation
Microprocessor Controlled
Auto diagnostic System
Continuously Monitoring of the remaining X-Ray Tube Heat Units
Three Point Console
Power 32 kW. kVp Range from 40 kVp to 125 kVp in 1 kVp Steps
mA Range from Minimum 10 mA to Maximum 320 mA. Renard Scale
16 mA Stations. 10, 12,5, 16, 20, 25, 32, 40, 50, 64, 80, 100, 125,160, 200, 250, 320, mA.
Time range from 1 ms. to 10 sec. 41 Time Stations. Renard Scale
mAs range from 0.1 mAs to 500 mAs.38 mAs Station. Renard Scale
Home Page
Our Company
Our Services
Our Products
Q&A Forum
Contact Us
Search
C Arms
High Frequency Generators
Hospital Grade Systems
Line Frequency Generators
Orthopedic X-ray Systems
Podiatry X-ray Systems
Portable X ray Systems
TXR / Tingle X-ray
Veterinary X-ray Systems
from United Radiology Systems
What is a C Arm?
from Tingle
What is a High Frequency Generator?
from Tingle
What is a Hospital Grade System?
from Tingle TXR X-ray
What is a Line Frequency Generator?
from United Radiology Systems
What is a Orthopedic X-ray System?
from Source Ray
What is a Podiatry X-ray System?
from General Electric
from Tingle TXR X-ray
What is a portable X ray System?
from Tingle
What is a Veterinary X ray System
Medical Displays
Medical Imagers
from Dome
from NDS Surgical Imaging
What is a Medical Display?
EndoVue
LifeVue
Radiance
from Fuji
What is a Medical Imager?
Computed Radiography (CR)
Direct Radiography (DR)
from Fuji
from iCRco
What is CR?
from Tingle TXR X-ray
What is DR?
PACS by Essimed
What is PACS?
Parts
Accessories